Electra Elite IPK II Document Revision 4C
IP Trunk (SIP) – MG16 2 - 589
SIP NAPT Router Setup
10-12-06 CPUII Network Setup – NAPT Router
Enable (1)/Disable (0) the NAPT Router Setup. With SIP trunking behind a NAPT Router, this
must be set to 1.
(Default: 0)
10-12-07 CPUII Network Setup – NAPT Router IP Address
Set the NAPT Router IP address. With SIP trunking, the IP address of the WAN side of the
router must be entered.
(Default=0.0.0.0)
10-12-08 CPUII Network Setup – ICMP Redirect
Enable (1)/Disable (0) ICMP (Internet Control Message Protocol) Redirect.
(Default: 0)
SIP System Interconnect Setup
10-23-01 SIP System Interconnection Setup – System Interconnection
Enable (1)/Disable (0) the system interconnection to another system
(Default: 0)
10-23-02 SIP System Interconnection – IP Address
Define the IP address of another system.
Entries:
0.0.0.0 ~ 126.255.255.254
128.0.0.1 ~ 191.255.255.254
192.0.0.1 ~ 223.255.255.254
(Default: 0.0.0.0)
10-23-04 SIP System Interconnection Setup – Dial Number
Determine another system call control port number
Entries: Up to 12 digits (0~9)
(Default = None)
SIP Protocol
84-14-06 SIP Trunk Basic Information Setup – SIP UA Trunk Port
Set the SIP UA (User Authorized) Trunk port number (1~65535) receiving transport for Electra
Elite IPK II SIP).
(Default: 5060)
84-14-07 SIP Trunk Basic Information Setup – Session Timer Value
Set the Session Time (0~65535 seconds).
(Default: 0 (session timer Off)
84-14-08 SIP Trunk Basic Information Setup – Minimum Session Timer Value
Set the Minimum Session Time (0~65535 seconds).
(Default: 1800)