Document Revision 4C Electra Elite IPK II
2 - 688 Long Conversation Cutoff
Related Features
Central Office Calls, Answering
Central Office Calls, Placing
Direct Inward System Access (DISA)
Tie Lines
Warning Tone for Long Conversation
Programming
14-01-14 Basic Trunk Data Setup – Long Conversation Cutoff
Enable (1)/Disable (0) a trunk user ability to disconnect incoming and outgoing central office
calls automatically.
14-01-15 Basic Trunk Data Setup – Long Conversation Alarm Before Cut Off
Enable (1)/Disable (0) the Long Conversation Alarm for each trunk.
20-06-01 Class of Service for Extensions
Assign a Class of Service (1~15) to extensions.
20-13-02 Class of Service Options (Supplementary Service) – Long Conversation Cutoff
(Incoming)
Enable (1)/Disable (0) the ability of an extension Class of Service to use Long Conversation
Cutoff for incoming calls.
20-13-03 Class of Service Options (Supplementary Service) – Long Conversation Cutoff
(Outgoing)
Enable (1)/Disable (0) the ability of an extension Class of Service to use Long Conversation
Cutoff for outgoing calls.
(default: 0)
20-21-03 System Options for Long Conversation – Long Conversation Cutoff for Incoming Call
Enter the time the system waits before disconnecting incoming trunks (0~64800 seconds).
(default: 0)
20-21-04 System Options for Long Conversation – Long Conversation Cutoff for Outgoing Call
Enter the time the system waits before disconnecting outgoing trunks (0~64800 seconds).
(default: 0)

Table of Contents