Document Revision 4C Electra Elite IPK II
2 - 48 Analog Communications Interface (ACI)
The devices connected to the PGD(2)-U10 ADP must be compatible with the specifications
below. Refer to the Electra Elite IPK II System Hardware Manual for installation details.
Default Settings
No PGD(2)-U10 ADPs programmed.
System Availability
Terminals
None
Required Component(s)
PGD(2)-U10 ADP
PGD(2)-U10 ADP
/ACI Interface Specifications
Relay Contacts
Maximum Contact Ratings 30 V DC @ 60 mA
90 V AC @ 10 mA
Minimum Application Load 1 V DC @ 1 mA
Audio/Music Input
Input Impedance 47 K Ohms @ 1 K Hz
Maximum Input 0.4Vrms or 1.0Vp-p.
Audio/Paging Output
Output Impedance 600 Ohms @ 1 K Hz
Maximum Output + 3 dBm