Electra Elite IPK II Document Revision 4C
Multiline Conference Bridge 2 - 717
Operation
Setup Procedures
To set the Supervisor Password:
1. Call the Conference Bridge extension number, and wait for the voice prompt.
2. Dial the default Supervisor Password (0 0 0 0), then dial #.
3. Follow the voice prompt, and enter the setting verification mode (#). Then enter system set mode.
4. Follow the voice prompt to change Supervisor Password (4~8 digits).
To set the Conference 1 and/or the Conference 2 Password:
1. Call the Conference Bridge extension number, and wait for the voice prompt.
2. Dial the default Supervisor Password (0 0 0 0), then dial #.
3. Skip the steps until Conference Setup mode is available for conference 1 or conference 2.
4. Follow the voice prompt, and set the conference 1 or the conference 2 password (4~8 digits).
To record new Customized Greeting:
1. Call the Conference Bridge extension number, and wait for the voice prompt.
2. Dial the default Supervisor Password (0 0 0 0), then dial #.
3. Skip options until the Customized Greeting option is selected.
4. Follow the voice prompt and record new a Customized Greeting.
Operating Procedures
To start a Conference Call at an internal extension:
1. Call the Conference Bridge extension number.
2. When you hear the voice prompt, enter the Conference Bridge 1 or 2 password, and dial #.
3. Start the conference.
To start a conference call using outside DID:
1. Call the DID number for the Conference Bridge.
2. When the voice prompt is heard, enter the Conference Bridge 1 or 2 password, and dial #.
3. Start the conference.