Document Revision 4C Electra Elite IPK II
2 - 726 Multiple Trunk Types
ISDN BRI
Refer to the ISDN Compatibility on page 2-635 feature for related information.
ISDN PRI
Refer to the ISDN Compatibility on page 2-635 feature for related information.
T-1 Trunks
Refer to the T1 Trunking (with ANI/DNIS Compatibility) on page 2-941 feature for related information.
Conditions
Each TLI(2)-U( ) ETU supports two 4-wire E&M Tie Lines.
Each COI(8)-U( ) ETU has eight switches (one for each port) that can be used to select
either Loop or Ground Start per trunk.
Each COIB(4)-U10 ETU has four switches (one for each port) that can be used to select
either Loop or Ground Start per trunk.
Ground Start Trunks do not support Caller ID.
ETU
Caller
ID
CO Message
Waiting
Indication
Pad
Control
Loop
Start
Ground
Start
Fax
Branch
COI(4)-U10 X X
COI(8)-U10 X X
COID(4)-U10 X X X
COID(8)-U10 X X
COIB(4)-U10 X X X X
COIB(4)-U20 X X X X
COIB(4)-U30 X X X X X
COIB(8)-U20 X X X
COIB(8)-U30 X X X X
Caller ID is not supported for Ground Start trunks.