Document Revision 4C Electra Elite IPK II
2 - 730 Multiple Trunk Types
21-05-01 Toll Restriction Class – International Call Restriction Table
21-05-02 Toll Restriction Class – International Call Permit Code Table
21-05-04 Toll Restriction Class – Maximum Number of Digits Table Assignment
21-05-05 Toll Restriction Class – Common Permit Code Table
21-05-06 Toll Restriction Class – Common Restriction Table
21-05-07 Toll Restriction Class – Permit Code Table
21-05-08 Toll Restriction Class – Restriction Table
21-05-09 Toll Restriction Class – Restriction for Common Speed Dials
21-05-10 Toll Restriction Class – Restriction for Group Speed Dials
21-05-11 Toll Restriction Class – Intercom Call Restriction
21-05-12 Toll Restriction Class – PBX Call Restriction
If Program 34-01-05 is set to (1), define the toll restriction settings for Tie Lines.
21-05-13 Toll Restriction Class – Restriction of Tie Line Calls
Enable (1)/Disable (0) toll restriction for Tie Line calls (defined in Program 34-08-01).
22-02-01 Incoming Call Trunk Setup
For each Night Service mode, enter service type 5 when the trunk should be a tie trunk.
34-01-01 E&M Tie Line Basic Setup – DID/E&M Start Signaling
Enter 2nd dial tone (0), Wink (1), Immediate (2), or Delay (3) start signaling. To set outgoing
signaling, refer to Program 14-02-01
(default: 1)
34-01-03 E&M Tie Line Basic Setup – E&M Dial-In Mode
Determine if the incoming Tie Line call should be directed as an intercom call (0) or if it should
follow the DID Translation Table in Program 22-11-01 (1).
(default: 0)
34-01-04 E&M Tie Line Basic Setup – E&M Line Dial Tone
Enable (1)/Disable (0) the Tie Line dial tone.
(default: 1)
34-01-05 E&M Tie Line Basic Setup – System Toll Restriction
Turn Off (0) or On (1) the System Toll Restriction for Tie Line calls to follow the system toll
restriction entries in Program 21-05-01 through Program 21-05-13. If Off, Tie Line toll restriction
is determined by PRG 21-05-13.
(default: 0)