2 - 52 Chapter 2
Chapter 2 - Blade Installation and Startup
2.5.5 Digital/SLT Combination Blade (082U) (Figure 2-26) - P/N 0911058
The Digital/SLT Combination blade provides 8 digital ports and 2 analog ports. This blade allows for
either a 4COIU analog trunk daughter board or 2BRI daughter board to be installed.
The blade provides:
● 8 digital ports
● 2 analog ports
● 2 status LEDs
Without a MEMDB installed, only 1 082U blade can be installed in the system. With a MEMDB,
multiple 082U blades can be installed in the communications server - however, only one 082U blade
can be installed in a 9.5” base chassis or 1 per 19” chassis (for a maximum of 4 082U blades per
communications server). When connecting this blade, the system uses 8 digital port and 2 analog
ports. The blade consumes 10 logical ports (2 analog, 2 digital) plus any ports used by any attached
daughter board.
Blade Maximum’s
9.5”
Chassis
19” Chassis
w/CCPU
19” Chassis w/o
CCPU
19” Chassis x4
System Max. w/
Networking
1 1 Without MEMDB: 1
per System
With MEMDB: 1 per
19” Chassis
Without MEMDB: 1
per System
With MEMDB: 1 per
19” Chassis
4
(Without MEMDB: 1
per System
With MEMDB: 1 per
19” Chassis)
● Blades with “IP3NE” included as part of the blade name printed on the card
cannot be combined with any “IP3WW” version blades. The “IP3NE” are U.S.
versions, while the “IP3WW” are international versions of the blades.