4 - 30 Chapter 4
Chapter 4 - Terminals and Optional Equipment
Figure 4-18: 2PGDAD CABLE CONNECTION
4.9.3 Programming
● 10-03-01 : Blade Setup - Terminal Type (Circuit 1)
10-03-06 : Blade Setup - Terminal Type (Circuit 2)
Confirm that the 2PGDAD has defined the circuit types as either type “7” for External Ringer or “9”
for ACIs. (If the 2PGDAD circuit had previously been defined for another type of circuit, unplug the
2PGDAD and plug it back in order to reset the circuit types.)
● 10-05-01 : General Purpose Relay Setup
Define which relay circuits (5-8) on the 2PGDAD Module are used for General Purpose Relays.
● 11-06-01 : ACI Extension Numbering
Assign extension numbers to ACI software ports (1-96). Select a number outside of the normal
extension number range.
● 11-08-01 : ACI Group Pilot Number
Assign pilot numbers to ACI groups (1-16). When a user dials the pilot number, they reach an
available ACI software port within the group.
● 11-12-50 : Service Code Setup (For Service Access)
Specify the service code to be used for toggling the relay open and closed (Default: 880).
0893100 - 160
PGDAD Module
To ESIU PCB
CN2 or CN3
CN1
CN2
CN3
External Ringer
OR
External Recording System