EasyManua.ls Logo

NEC UX5000 - Trunk Blades; Analog Trunk (4 COIU) Blade (Figure 2-30) - P;N 0911072

NEC UX5000
370 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 2 - Blade Installation and Startup
Chapter 2 2 - 63
SECTION 2-7
Trunk Blades
2.7.1 Analog Trunk (4COIU) Blade (Figure 2-30) - P/N 0911072
The 4COIU is used to provide 4 ports for loop/ground start trunks. The blade can accept a 4COIDB to provide
an additional 4 ports (refer to 2.7.2 Analog Trunk (4COIDB) Daughter Board (Figure 2-31) - P/N 0911074 on
page 2-66).
The COIU blade provides:
4 analog loop start/ground start trunk circuits
1 trunk status LED
1 blade status LED
4 Caller ID Circuits
2 Power Failure Transfer Circuits
Connection for COIDB Daughter Board
Figure 2-30: 4COIU BLADE
CN2(COIU)
Analog Trunk
From Central Office
for Interface Circuit.
#1-#4
CN3
SLT I/F for
Power Failure
Transfer
#1-#2
CN1
CN4
Trunk I/F Circuit #4
Daughter Board I/F
(for COIU/082U)
CN5
Common
Control
Circuit
BUSY LED
(Status for Trunk Lines)
ON: Trunk in Use
OFF: Idle
LIVE LED
(Status LED)
Pin Number
Location
8
7
6
5
2
1
CN2(COIDB)
Analog Trunk
From Central Office
for Interface Circuit.
#5-#8
Trunk I/F Circuit #3
Trunk I/F Circuit #2
Trunk I/F Circuit #1
Trunk I/F Circuit #1
Trunk I/F Circuit #2
Trunk I/F Circuit #3
Trunk I/F Circuit #4

Table of Contents