Chapter 1 - Installing the Chassis
Chapter 1 1 - 33
SECTION 1-7
Mounting the Chassis
1.7.1 Mounting Options for the Chassis
The chassis can be set up or mounted in the following ways:
● Wall Mount (page 1-35 and page 1-45)
● Desktop (page 1-50)
● Floor Mount (page 1-54, page 1-57, page 1-59 and page 1-64)
● Rack-Mount (page 1-67)
1.7.2 Securing the Chassis to the Wall (Figure 1-47 - Figure 1-59)
If you choose to wall-mount the system, make sure the wall can support the weight of the chassis (20 lbs per
chassis). Ensure that enough space is available to allow the installation of the additional chassis above and
below the chassis. Be sure to mount the chassis sideways (as shown below). For proper air circulation/cooling,
the KSU-B/E chassis should never be mounted long ways.
.
Figure 1-46: WALL MOUNTING POSITION FOR CHASSIS-B/E
Position OK
Position Improper
X
OK