EasyManua.ls Logo

NEC UX5000 - Blade Load Factors

NEC UX5000
370 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 2 - Blade Installation and Startup
Chapter 2 2 - 13
SECTION 2-3
Blade Load Factors
In addition to the blade capacities listed on the previous pages, you must take into consideration the power
load factors for certain blades as well as station equipment (such as terminals, terminal adapters, and
consoles).
The maximum load factor for blades per system chassis (either 9.5” Chassis-B/E or 19” Chassis-A) is 7. The
maximum load factor for station equipment is either 64 (for 9.5” Chassis-B/E) or 80 (for 19: Chassis-A).
Refer to the following charts to determine the load factor for your equipment. Any blades or devices not
listed in these charts should not require consideration when determining the load factor (such as the
MEMDB or voice mail daughter board). Keep in mind that each 19” chassis (either 2 9.5” chassis combined
or 1 19” chassis) has a maximum number of timeslots for audio of 104. This means that any blade
combination within one system chassis cannot exceed 104 station or trunk ports.
Make additional copies of these pages for each chassis to be configured.
Blade Load Factor Table
Each Blade Load Factor Number Installed Total
CCPU 1
RTU 2
APSU 2
GSW 2
PVAU 1
32VOIPDB 1
64VOIPDB 2
128VOIPDB 2
The total number cannot exceed 7 for a 9.5” Chassis-B/E or 19” Chassis-A.
The Station Equipment Load Factor must also be considered.

Table of Contents

Other manuals for NEC UX5000

Related product manuals