EasyManua.ls Logo

NEC UX5000 - Installing Cables; Installing Extension Cross-Connect Blocks; Installing Trunk Cross-Connect Blocks

NEC UX5000
370 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 3 - Installing Extensions and Trunks
Chapter 3 3 - 5
SECTION 3-4
INSTALLING CABLES
3.4.1 Installing Extension Cross-Connect Blocks
It is recommended to install cross-connect blocks for each of the system's major extension port device groups.
Cross-connect blocks provide an easy way to troubleshoot, determine port identification numerically, and
determine port utilization.
Install cross-connect blocks for the following interfaces:
All digital extension circuits
CCPU functions (i.e.; BGM, MOH, relay 1)
External page
External alarms
Data devices
3.4.2 Installing Trunk Cross-Connect Blocks
It is also recommended to install cross-connect blocks for each of the system's major trunk device groups.
Cross-connect blocks provide an easy way to troubleshoot, determine port identification numerically, and
determine trunk port utilization.
Install cross-connect from telcos RJ21X to the trunk cross-connect blocks for the following:
analog loop start lines
analog ground start trunks
DID trunks
Tie lines