Chapter 2 - Blade Installation and Startup
Chapter 2 2 - 103
6. In the firmware update window, browse to the location of the Firmware Package file. For
example, the file name might be 3_00 MEMDB FW.mem.
● There are separate files for use with non-MEMDB systems or with a MEMDB installed.
Select the correct file for your application.
7. Select the schedule type:
● Immediately after upload
● At the time...
If you choose "At the time...", select the date and time you want the CCPU to reset and
switch over to the new software version.
8. Click Start. PCPro uploads the firmware package file and updates the UX5000 at the time you
specified in step 7.