4 - 28 Chapter 4
Chapter 4 - Terminals and Optional Equipment
6. Plug a modular line cord from the mod jack to the CN1 connector on the 2PGDAD module.
7. Connect the two-conductor station cable from the CN5 connectors within the 2PGDAD
module to the external relay.
8. Follow the feature programming as described in the UX5000 Feature Manual (P/N 0913201).
Figure 4-17: CCPU PAGE CONNECTIONS
The relay closes when the Door Box/external page zone is called. The
maximum applied voltage is 24vDC at .5A for each contact.
Page Controller
Amplifier
Page Audio
Input
Page Control
Relays
Page Speaker
CCPU PCB
CN8
CN9
Cross
Connect
Block