8-Port Gigabit (PoE+) Ethernet Smart Managed Pro Switch with (2 SFP or 2 Copper Ports and)
Cloud Management
Maintain or Troubleshoot the Switch User Manual459
4. Enter one of the following passwords:
• After registration, enter the local device password.
By default, the local device password is password.
• If you previously managed the switch through the Insight app or Cloud portal, enter
the Insight network password for the last Insight network location.
For information about the credentials, see
Credentials for the local browser interface on
page 32.
5. Click the Login button.
The System Information page displays.
6. Select Maintenance > T
roubleshooting > Traceroute IPv6.
7. In the IPv6 Address/Host Name field, enter the IPv6 address or host name of the device for
which the path must be discovered.
8. In the Probes Per Hop field, enter the number of probes per hop.
The default value is 3. The range is 1 to 10.
9. In the Max TTL field, enter the maximum time to live (TTL) for the destination.
The default value is 30. The range is 1 to 255.
10. In the Init TTL field, enter the initial
TTL to be used.
The default value is 1. The range is 1 to 255.