Training Guide Course No. 196514
Level 2 Maintenance, X-1000 Series Dispensing Systems 4-19 P/N 196515 (Revision A)
Press the black OFF (0) button
on the Operator's Console.
Cable (P/N 06-4515-00)
has failed.
Is the +24V LED
illuminated?
Power Manager (P/N 62-
1620-01) has failed
Switch the Main Circuit Breaker
to the OFF (0) position.
Disconnect +24V Power Cable
(P/N 06-4510-00) from Main
Interface Board +24V POWER
IN connector.
Switch the Main Circuit Breaker
to the ON (I) position.
Press the green ON (I) button on
the Operator's Console.
Measure VDC between Pin 1 and
Pin 2 on the +24V Power Cable
(P/N 06-4510-00).
Is the reading greater
than 23 VDC?
Press the black OFF (0) button
on the Operator's Console.
Is the reading greater
than 23 VDC?
Press the black OFF (0) button
on the Operator's Console.
Switch the Main Circuit Breaker
to the OFF (0) position.
Disconnect the +24V Power
Cable (P/N 06-4510-00) from the
Main Power Manager +24V DC
POWER OUT connector.
Switch the Main Circuit Breaker
to the ON (I) position.
Press the green ON (I) button on
the Operator's Console.
Measure VDC between Pin 1 and
Pin 2 at the Power Manager
+24V DC POWER OUT
connector.
Switch the Main Circuit Breaker
to the OFF (0) position.
Reconnect the DC Power Cable
(P/N 06-4530-00) to the Main
Interface Board XY Servo DC
Power connector.
Switch the Main Circuit Breaker
to the ON (I) position.
Press the green ON (I) button on
the Operator's Console.
A
Locate the power LEDs on
the Main Interface PWA.
NoYes
No Yes
Yes
No
Press the black OFF (0) button
on the Operator's Console.
Cable (P/N 06-4515-00)
has failed.
Is the +24V LED
illuminated?
Is the +24V LED
illuminated?
Power Manager (P/N 62-
1620-01) has failed
Switch the Main Circuit Breaker
to the OFF (0) position.
Disconnect +24V Power Cable
(P/N 06-4510-00) from Main
Interface Board +24V POWER
IN connector.
Switch the Main Circuit Breaker
to the ON (I) position.
Press the green ON (I) button on
the Operator's Console.
Measure VDC between Pin 1 and
Pin 2 on the +24V Power Cable
(P/N 06-4510-00).
Is the reading greater
than 23 VDC?
Is the reading greater
than 23 VDC?
Press the black OFF (0) button
on the Operator's Console.
Is the reading greater
than 23 VDC?
Is the reading greater
than 23 VDC?
Press the black OFF (0) button
on the Operator's Console.
Switch the Main Circuit Breaker
to the OFF (0) position.
Disconnect the +24V Power
Cable (P/N 06-4510-00) from the
Main Power Manager +24V DC
POWER OUT connector.
Switch the Main Circuit Breaker
to the ON (I) position.
Press the green ON (I) button on
the Operator's Console.
Measure VDC between Pin 1 and
Pin 2 at the Power Manager
+24V DC POWER OUT
connector.
Switch the Main Circuit Breaker
to the OFF (0) position.
Reconnect the DC Power Cable
(P/N 06-4530-00) to the Main
Interface Board XY Servo DC
Power connector.
Switch the Main Circuit Breaker
to the ON (I) position.
Press the green ON (I) button on
the Operator's Console.
A
Locate the power LEDs on
the Main Interface PWA.
NoYes
No Yes
Yes
No
Diagram Sheet 4-2-12
System Power Fault Isolation Procedure - XY Servo Power Verification

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Nordson Asymtek X-1020 and is the answer not in the manual?

Nordson Asymtek X-1020 Specifications

General IconGeneral
BrandNordson
ModelAsymtek X-1020
CategoryDispenser
LanguageEnglish

Related product manuals