EasyManua.ls Logo

Oce 9300 - Océ 9300 Printer Safety Data Sheet

Oce 9300
121 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
112 Océ 9300 User Manual
Safety data sheet Océ 9300 printer
The contents of this safety data sheet is subject to the disclaimer on page 111
of this manual.
PRODUCT SAFETY DATA SHEET
Number E-708-a-US
Date August 1999
Copyright © 1999 Océ-Technologies B.V., Venlo, NL
Model Océ 9300
Description Electrostatic printer, instant printing, console model, plain paper, organic photoconductive
drum, powder toner
Max. process speed 3 m/min
Dimensions Width
1roll 2roll
1352 mm 1352 mm
Depth 918 mm 918 mm
Height 1251 mm 1251 mm
Weight 149 kg 159 kg
Voltage 115 V
Frequency 60 Hz
Current-rated 15 A
Current-max 20 A
Power consumption 1500 W at continuous operation
Power consumption, stand by 46 W
Mains connection Cable with plug
Safety class I (IEC 536) Protective earth connection
Protection class IP 20 (IEC 529)
Sound pressure level
(at bystander position)
Stand by In operation
0 dB(A) main body 51 dB(A)
impulse L
i
= 2 dB(A)
Sound power level 0 dB(A) main body 61 dB(A)
Radio interference Complies with FCC rules and regulations, part 15 class A
Radiation Below the Threshold Limit Values for UV, Visible and IR radiation (TLV list of ACGIH)
Heat emission Standby 46 W; at continuous operation 1500 W
Ozone emission 0,02 mg/min at continuous operation
Room volume Recommendation: min. 25 m
3
Room ventilation Recommendation: min. 12,5 m
3
/h (natural ventilation)
Use simulation at random
operation
With a room volume and ventilation as recommended and a daily volume of 100 m (much
more than average) the use simulation at random operation gives the following ozone
concentrations:
- Time weighted average 0,002 mg/m
3
(0,001 ppm)
- Peak 0,008 mg/m
3
(0,004 ppm)
Threshold Limit Value/Occupational Exposure Limit
(Time Weighted Average) for ozone 0,2 mg/m
3
(0,1 ppm)
Odour Perception Limit for ozone 0,04 mg/m
3
(0,02 ppm)
Consumables Océ OPC Drum (Océ Safety Data Sheet E-218)
Océ B4 Toner (Océ Safety Data Sheet E-196)
Océ D4 Developer (Océ Safety Data Sheet E-197)
Océ Copying Materials.
This apparatus is suitable for processing recycling paper. Ask Océ for suitable recycling
paper.
Additional safety information The ozone ?lter does not have to be replaced to keep the ozone concentration in the
workplace below 0,04 mg/m
3
(i.e. the life of the ?lter equals that of the apparatus).
Listed according to standard UL 1950 and CAN/CSA-C22.2 No.950
LISTED 927F
INFORMATION
TECHNOLOGY
EQUIPMENT
E 69871

Table of Contents