Soft Lock Function
Use this function to prohibit writing of each parameter. This helps prevent data rewrite due to
erroneous operation.
For the soft lock selection through the signal input from the terminal (b031 = 00 or 01), refer to the
Soft Lock Function of the Multi-function Input section in "Reset" (page 4-50).
Allocate 15 (SFT) to the desired multi-function input.
Overload warning level
C041
Output current
OL
Overload limit level
b022
Parameter No. Function name Data Default setting Unit
b031
Soft lock
selection
00: Data other than b031 cannot be changed when
terminal SFT is ON.
01: Data other than b031 and specified frequency
parameters cannot be changed when terminal
SFT is ON.
02: Data other than b031 cannot be changed.
03: Data other than b031 and the specified frequency
parameter cannot be changed.
10: Data other than parameters changeable during
operation cannot be changed.
01
Related parameters SFT input
Data Symbol Function name Status Description
15 SFT Soft lock
ON
Rewriting is unacceptable except for specified
parameters.
OFF Depends on the b031 setting.
Related parameters
C001 to C005
Required settings b031 (soft lock excluded)