4-40
4-2 Function Mode
4
Functions
Carrier Frequency
You can change the PWM waveform carrier frequency output from the Inverter.
With the carrier frequency set high, you can reduce metallic noise from the motor. However, this
may increase electrical noise or leakage current from the Inverter.
Carrier frequency adjustment also helps avoid mechanical or motor resonance.
To raise the carrier frequency, reduce the output current (or derate the rated current) as shown in
the graph below.
Parameter No. Function name Data Default setting Unit
b083 Carrier frequency 2.0 to 12.0 3.0 kHz
4 6 8 10 12
100%
95%
90%
85%
80%
75%
70%
60%
65%
2
200-V Class
0.2/0.4/2.2/5.5kW
1.5kW
7.5kW
4 6 8 10 12
100%
95%
90%
85%
80%
75%
70%
60%
65%
2
400-V Class
5.5kW
2.2kW
3.7kW
0.4 to 1.5/7.5kW
0.75kW
3.7kW
4 6 8 10 12
Output current (Rated current %)
100%
95%
90%
85%
80%
75%
70%
2
Carrier frequency [kHz]
(3) Side-By-Side installation (ambient temperature:40°C)
200-V Class
3.7 kW
0.2 to 2.2 · 5.5/7.5kW
4 6 8 10 12
100%
95%
90%
85%
80%
75%
70%
2
400-V Class
5.5/kW
7.5kW
3.7kW
0.4 to 2.2kW
Output current (Rated current %)
Carrier frequency [kHz]
(2) Ambient temperature 50°C
Output current (Rated current %)
Output current (Rated current %)
Carrier frequency [kHz] Carrier frequency [kHz]
4 6 8 10 12
100%
95%
90%
85%
80%
75%
2
200-V Class
0.2 to 2.2 · 5.5/7.5kW
3.7kW
(1) Ambient temperature 40°C
Output current (Rated current %)
Carrier frequency [kHz]
4 6 8 10 12
100%
95%
90%
85%
80%
75%
2
400-V Class
0.4 to 2.2 · 5.5/7.5kW
3.7kW
Output current (Rated current %)
Carrier frequency [kHz]

Table of Contents

Other manuals for Omron JX

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron JX and is the answer not in the manual?

Omron JX Specifications

General IconGeneral
Enclosure RatingIP20
Output Frequency0 to 400 Hz
ProtectionOvercurrent, Overvoltage, Undervoltage, Overheat, Short Circuit
CommunicationRS-485
Frequency Range0.1 to 400 Hz
Power Rating0.4 to 15 kW
Operating Temperature-10°C to +50°C
Storage Temperature-20°C to +65°C
Humidity5 to 95% RH (non-condensing)
AltitudeUp to 1000 m above sea level
Output Voltage3-phase 200 to 240 VAC, 3-phase 380 to 480 VAC
Cooling MethodFan cooling