4-61
4-2 Function Mode
4
Functions
Multi-function Output Terminal Contact Selection
This function allows you to set either contact for the two multi-function output terminals respectively.
Original signal waveform
(without delay)
ON delay only
OFF delay only
ON and OFF delays
ON delay ON delay
OFF delay
OFF delay
Parameter No. Function name Data Default setting Unit
C031
Multi-function output
terminal 11 contact
selection
00: NO contact
01: NC contact
00
C036
Relay output (AL2, AL1)
contact selection
00: NO contact between AL2 and AL0
01: NC contact between AL2 and AL0
01