5-4
5-1 Special Display List (Error Codes)
5
Maintenance Operations
Other Displays
Name Description
Display on Digital
Operator
Reset Appears with the [RS] terminal turned ON or during initialization.
Undervoltage
standby
Appears when the Inverter is in the undervoltage standby condition or
with the power shut off.
Restart during
momentary power
interruption
Restart during trip
The restart function is in operation.
Setting initialization Appears while the set values are being initialized.
Trip monitor
initialization
Appears while the trip monitor is being initialized.
No data
Appears if no data exists.
(Trip monitor)
Communications
error
Appears if an error occurs between the Digital Operator and the
Inverter.
0 0

Table of Contents

Other manuals for Omron JX

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron JX and is the answer not in the manual?

Omron JX Specifications

General IconGeneral
Enclosure RatingIP20
Output Frequency0 to 400 Hz
ProtectionOvercurrent, Overvoltage, Undervoltage, Overheat, Short Circuit
CommunicationRS-485
Frequency Range0.1 to 400 Hz
Power Rating0.4 to 15 kW
Operating Temperature-10°C to +50°C
Storage Temperature-20°C to +65°C
Humidity5 to 95% RH (non-condensing)
AltitudeUp to 1000 m above sea level
Output Voltage3-phase 200 to 240 VAC, 3-phase 380 to 480 VAC
Cooling MethodFan cooling