3-13
3-4 Operation Procedure (Example: Factory Default)
3
Operation
Setting Function Codes
You can enter codes for the monitor mode, basic function mode, and extended function mode
directly, as well as through the scrolling method.
Below is an example where code d001 of the monitor mode is changed to extended function A029.
(Change the A002 setting.)
Change the RUN command selection to the
terminal "01".
4. The code of the monitor mode is displayed (as "A002").
Press the Enter key to fix the changed setting
data.
The RUN command selection is changed to the
terminal, and the RUN command LED indicator
will go off.
You can now change to another extended
function code.
5. The extended function mode is displayed (as "A---").
You can now move to another extended function
mode, the monitor mode, and the basic function
mode.
1. Display the code of the monitor mode (as "d001").
(Continued to the next page)
01
Press
a002
(3 times)
Press
a---
d001
Press and simultaneously