3-5
3-2 Test Run Operation
3
Operation
Parameter Initialization
Initialize the parameters using the following procedure.
To initialize the parameters, set parameter b084 to "02".
Key sequence Display example Description
Power On
Press the Mode key once, and then press the Decrement key three times to
display "b---".
Press the Mode key.
"b001" is displayed.
Use the Increment or Decrement key to display "b084".
Press the Mode key. The set value in "b084" is displayed.
Use the Increment or Decrement key to display "02".
Press the Enter key. The set value is entered and "b084" is displayed.
Press the STOP/RESET key while holding down the Mode and Decrement
keys simultaneously.
When the display blinks, release the STOP/RESET key first, and then the
Mode and Decrement keys.
Displays initialization.
(In 1 s) The parameter number is displayed again in approximately 1 s.
0.0
b---
b001
b084
00
02
b084
=k.k0k0
d001