EasyManuals Logo

Omron JX User Manual

Omron JX
220 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #21 background imageLoading...
Page #21 background image
1-3
1-1 Functions
1
Overview
Compact Simplified Inverter for Customer's Environment and
Application Demands
Simple Wiring and Easy Installation
The main circuit adopts upper/lower wiring as with a conductor. In addition, the side-by-side
mounting of the Inverters and the built-in zero-phase reactor contribute to space saving in control
panel.
Wide Ranging Capacity and Power Supply
In spite of its compact size, the JX Inverter provides a wide ranging capacity from 0.2 to 7.5 kW.
Moreover, the three-phase 200 V, three-phase 400 V, and single/three-phase 200 V common types
are made to meet the power supply specifications for use outside Japan.
PID Function
The PID function is featured for the easier control of the fan and pump. It helps to control airflow and
pressure.
Emergency Shutoff Function
Switching the dedicated switch (S8) changes from the multi-function input (input 3) to the
emergency shutoff input. You can directly turn off a motor control power module without operating
the software.
Compliance With Standards
The JX Series has achieved compliance with CE and UL/cUL.
The RoHS Directive
The standard model meets the requirements of the RoHS Directive.
Noise and Harmonics Suppression Option
The three-phase models incorporate a zero-phase reactor (radio noise filter) as a standard
specification.
For the single/three-phase common type, optional suppression is available.
When the optional DC reactor is added, the JX Series will also meet the requirements specified by
the Ministry of Land, Infrastructure, Transport and Tourism of Japan.
Handles a Variety of I/O Signals
The JX Series can handle a variety of I/O signals for wide-ranging applications.
Analog voltage input: 0 to 10 V
Analog current input: 4 to 20 mA

Table of Contents

Other manuals for Omron JX

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron JX and is the answer not in the manual?

Omron JX Specifications

General IconGeneral
Enclosure RatingIP20
Output Frequency0 to 400 Hz
ProtectionOvercurrent, Overvoltage, Undervoltage, Overheat, Short Circuit
CommunicationRS-485
Frequency Range0.1 to 400 Hz
Power Rating0.4 to 15 kW
Operating Temperature-10°C to +50°C
Storage Temperature-20°C to +65°C
Humidity5 to 95% RH (non-condensing)
AltitudeUp to 1000 m above sea level
Output Voltage3-phase 200 to 240 VAC, 3-phase 380 to 480 VAC
Cooling MethodFan cooling

Related product manuals