Full Self Test — a thorough test that moves a tape to every slot and to every
unoccupied drive compatible with the chosen diagnostic tape. A full test can
take significant time depending on the number of modules in the library, so
plan accordingly.
5. Optionally, select Set the Library back Online to automatically bring the library
online after the test (the library goes offline to perform the self test)
6. Click OK to start the test.
Note:
If the test fails, click Degraded to open a health table identifying a failed
or degraded component. See Use the Health Table to Diagnose the
Issue more information.
7. If you did not check the Set the Library back Online checkbox, remember to
bring the library back online manually, once you are ready. See Place the Library
Online or Offline.
Stopping a Self-test
Stop a self-test to resume library operations.
To stop a test that is in progress, from the Library drop-down , select Stop
the current test. The test may take a few moments to stop. If the diagnostic cartridge
was not returned to its reserved cell at the end of the test, move the diagnostic
cartridge now.
Related Topics
Move Tape Cartridges with the Remote Interface
The remote interface can move cartridges when you cannot use the host
application.