Verify the Rear I/O Module
180 SPARC T5-4 Server Service Manual • July 2016
4.
Connect the cables to the appropriate ports on the rear I/O module.
5.
Connect the power cords.
See “Connect Power Cords” on page 191.
6.
Power on the server.
See “Returning the Server to Operation” on page 191.
7.
Verify the rear I/O installation.
See “Verify the Rear I/O Module” on page 180.
Related Information
■
“Rear I/O Module LEDs” on page 173
■
“Determine if the Rear I/O Module Is Faulty” on page 175
■
“Remove the Rear I/O Module” on page 176
■
“Verify the Rear I/O Module” on page 180
■
“Returning the Server to Operation” on page 191
Verify the Rear I/O Module
1.
Ensure that you have completed the following:
■
Applied power to the server.
See “Connect Power Cords” on page 191.
■
Started the system.
See “Power On the Server (Oracle ILOM)” on page 192.
2.
Verify that the System Service Required LED on the rear I/O module is not lit.
See “Rear I/O Module LEDs” on page 173.
3.
Log in to Oracle ILOM.
See “Log In to Oracle ILOM (Service)” on page 26.
4.
Start the faultmagmt shell.
-> start SP/faultmgmt/shell
Are you sure you want to start the faultmgmt shell (y/n)? y
faultmgmtsp>
5.
Use the fmadm faulty command to determine if the server is operating normally.