Verify the System Battery
128 SPARC T5-4 Server Service Manual • July 2016
timezone = PDT (PDT)
usentpserver = (none)
Commands:
cd
set
show
Note - For additional details about setting the Oracle ILOM clock, refer to the CLI Procedures
Guide for Oracle ILOM.
7.
Verify that the new system battery is functioning properly.
See “Verify the System Battery” on page 128.
Related Information
■
“Remove the System Battery” on page 125
■
“Verify the System Battery” on page 128
Verify the System Battery
1.
Run show /SYS/MB/V_BAT to check the status of the system battery.
In the output, the /SYS/MB/V_BAT status should be OK, as in the following example.
-> show /SYS/MB/V_BAT
Targets:
Properties:
type = Voltage
ipmi_name = MB/V_VBAT
class = Threshold Sensor
value = 3.140 Volts
upper_nonrecov_threshold = N/A
upper_critical_threshold = N/A
upper_noncritical_threshold = N/A
lower_noncritical_threshold = 2.704 Volts
lower_critical_threshold = N/A
lower_nonrecov_threshold = N/A
alarm_status = cleared
Commands:
cd
show
2.
Verify that the value in the Voltage column shows a voltage of approximately 2.8
V.
Related Information
■
“Remove the System Battery” on page 125