Determine if the Main Module Is Faulty
Servicing the Main Module 99
No. LED Icon Description
■ Steady on, amber – A SP error has occurred and service is required.
Related Information
■
“Determine if the Main Module Is Faulty” on page 99
■
“Remove the Main Module” on page 99
■
“Install the Main Module” on page 102
Determine if the Main Module Is Faulty
Check the Service Required LED on the main module.
The Service Required LED is lit when the server detects a main module fault.
Related Information
■
“Main Module LEDs” on page 98
■
“Remove the Main Module” on page 99
■
“Install the Main Module” on page 102
Remove the Main Module
1.
(Optional) If you are replacing a faulty main module, you must back up ILOM
configuration settings.
a.
Configure the SER MGT port to enable the configuration parameters to be
uploaded.
Refer to the ILOM documentation for network configuration instructions.
b.
Back up the ILOM configuration parameters.
See Oracle ILOM documentation.
2.
Shut down the server.
See “Removing Power From the Server” on page 51.
3.
Disconnect the power cords.
See “Disconnect Power Cords” on page 53.
4.
Locate the main module in the server.