Configuring POST
34 SPARC T5-4 Server Service Manual • July 2016
Properties Values Description
/HOST/diag trigger hw-change
(Default) Runs POST following a FRU replacement or an AC
power cycle.
all-resets
Runs POST on all resets.
error-reset
Runs POST on all error resets.
power-on-reset
Runs POST on every power on.
none
Does not run POST on reset.
/HOST/diag hw_change_level max
Runs the maximum set of tests.
min
Runs the minimum set of tests.
/HOST/diag
hw_change_verbosity
min
(Default) Displays the minimum level of output.
max
Displays information for each step.
normal
Displays a moderate amount of information, including
component names and test results.
debug
Displays extensive debugging information.
none Disables the output.
/HOST/diag power_on_level max
(Default) Runs the maximum set of tests.
min
Runs the minimum set of tests.
/HOST/diag
power_on_verbosity
min
(Default) Displays the minimum level of output.
max
Displays information for each step.
normal
Displays a moderate amount of information, including
component names and test results.
debug
Displays extensive debugging information.
none
Disables the output.
/HOST/diag error_reset_level max
(Default) Runs the maximum set of tests.
min
Runs a minimum set of tests.
/HOST/diag
error_reset_verbosity
min
(Default) Displays the minimum level of output.
max
Displays information for each step.
normal
Displays a moderate amount of information, including
component names and test results.
debug
Displays extensive debugging information.
none
Disables the output.
/HOST/diag verbosity normal
Displays all test and informational messages in POST output.
min
Displays functional tests with a banner and pinwheel in POST
output.
max
Displays all test, informational, and some debugging messages
in POST output.
debug
Displays extensive debugging information.
none
Does not display POST output.