Check for Faults
Detecting and Managing Faults 39
faultmgmtsp> fmadm faulty
------------------- ------------------------------------ ------------- -------
Time UUIDmsgidSeverity
------------------- ------------------------------------ ------------- -------
2012-08-27/19:46:26 4ec16c8d-5cdb-c6ca-c949-e24d3637ef27 PCIEX-8000-8R Major
Problem Status : solved
Diag Engine : [unknown]
System
Manufacturer : Oracle Corporation
Name : SPARC T5-8
Part_Number : 12345678+11+1
Serial_Number : 1238BDC0DF
----------------------------------------
Suspect 1 of 1
Fault class : fault.io.pciex.device-interr-corr
Certainty  : 100%
Affects   : hc:///chassis=0/motherboard=0/cpuboard=0/chip=0/hostbridge=0/
   pciexrc=0
Status : faulted but still in service
FRU
Status: faulty
Location: /SYS/PM0
Manufacturer: Oracle Corporation
Name : TLA,PN,NRM,T5 1.2
Part_Number : 7061001
Revision : 01
Serial_Number: 465769T+12445102WR
Chassis
Manufacturer : Oracle Corporation
Name :SPARC T5-8
Part_Number : 12345678+13+2
Serial_Number: 1248DC140
Description : A fault has been diagnosed by the Host Operation System.
Response : The service required LED on the chassis and on the affected
FRU may be illuminated.
Impact : No SP impact
Action : Refer to the associated reference document at
https://support.oracle.com/msg/PCIEX-8000-8R for the latest
service procedures and policies regarding this diagnosis.
faultmgmtsp>
In this example, a fault is displayed that includes these details:
Date and time of the fault (2012-08-27/19:46:26).
UUID (4e16c8d-5cdb-c6ca-c949-e24d3637ef27), which is unique to e h fault.