EasyManua.ls Logo

Panasonic DLP PT-RZ34K

Panasonic DLP PT-RZ34K
325 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 4Settings — [PROJECTOR SETUP] menu
186 - ENGLISH
5 Display the status by color.
Green: There is an allowance for brightness correction.
Yellow: There is little allowance for brightness correction.
Red: There is a brightness control error.
6 Display error detailed messages.
7 Display error messages.
When the message [Failed to apply BRIGHTNESS CONTROL to some projectors.] appears, it means that synchronization with the
projector displayed in red has failed.
Press as to select the projector displayed in red, and press the <ENTER> button to display the error details.
8 Update to the latest status information.
r Error details
Error message Measures to take
[Exceed maximum number of
projectors.]
f Limit the number of projectors in one group to eight.
f To synchronize nine or more projectors, use a computer and “Multi Monitoring & Control
Software”
*1
.
[Please check the COMMAND
CONTROL setting.]
f Set the password of the administrator account.
f Set [NETWORK CONTROL] [COMMAND CONTROL] to [ON] for the projector in error.
f Set [NETWORK CONTROL] [COMMAND PORT] of all linked projectors to the same value.
[Please check the USER NAME
and PASSWORD in the COMMAND
CONTROL setting.]
f Set the administrator account (user name and password) of all linked projectors to the same
setting.
[Cannot apply BRIGHTNESS
CONTROL. Please check projector
status.]
f The projector is in standby. Switch on the power.
[Brightness Sensor Error]
f There is a problem with the brightness sensor. If problems persist even after switching on the
power, consult your dealer.
*1 “Multi Monitoring & Control Software” can be downloaded from the Panasonic website (https://panasonic.net/cns/projector/).
Note
f If the synchronized projectors are not displayed in the list, check the following:
g Are there devices with the same IP address on the network?
g Are the LAN cables connected correctly? (x page 227)
g Are the subnets of the projectors the same?
g Are the same [LINK] settings applied to a group?
f Refer to [PROJECTOR NAME] (x page 217) or “[Network cong] page” (x page 243) on how to change the projector name.
Brightness control adjustment procedure example
The steps exemplify an adjustment to link the brightness of eight projectors connected in a network.
1) Connect all projectors to a switching hub using LAN cables. (x page 227)
2) Switch on all projectors and start projection.
3) Set [CONSTANT MODE] of [BRIGHTNESS CONTROL SETUP] to [OFF], and select [APPLY], and then
press the <ENTER> button.
4) Set [OPERATING MODE] of each projector to the same setting. (x page 180)
5) Set [SUBNET MASK] and [IP ADDRESS] in each projector.
f To be able to communicate over the network, set the same value in [SUBNET MASK] for all projectors and
set a different value in [IP ADDRESS] for each projector.
6) Wait for at least eight minutes after projection has started until the light source brightness becomes
steady.
7) Set all items in the [PICTURE] menu of all projectors to the same values.
8) Adjust [COLOR MATCHING] to match colors.
9) Display the internal test pattern “All white” in all projectors.
10) Set [LIGHT OUTPUT] of all projectors to 100 % or the maximum value that can be set.
f Depending on the [OPERATING MODE] settings, [LIGHT OUTPUT] may not be able to be set to 100 %.
11) Set [LIGHT OUTPUT] of the projector with the least brightness to 90 % or 10 % lower than the