EasyManua.ls Logo

Parker ac890 - Page 578

Parker ac890
640 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Programming
Page
D-228
890CS Common Bus Supply - Frames B & D; 890CD Common Bus Drive and 890SD Standalone Drive - Frames B, C & D
8
9
10
A
B
C
D
E
1
2
3
4
5
6
7
PREF Name Block Type Range Default ro\rw Notes
114.13 ENABLE DRIVE REGEN CNTRL BOOL 0 : FALSE
1 : TRUE
FALSE ro Output
114.14 STATUS REGEN CNTRL ENUM 0 : INACTIVE
1 : SYNCHRONIZING
2 : SYNCHRONIZED
3 : SUPPLY FRQ HIGH
4 : SUPPLY FRQ LOW
5 : SYNCH FAILED
INACTIVE ro Output
114.15 BRAKE MODE REGEN CNTRL BOOL 0 : FALSE
1 : TRUE
FALSE rw
115.01 INHIBIT SPD FBK TRIP BOOL 0 : FALSE
1 : TRUE
FALSE rw
115.02 THRESHOLD SPD FBK TRIP REAL 0.00 to 300.00 % 50.00 % rw
115.03 DELAY SPD FBK TRIP REAL 0.00 to 300.00 s 10.00 s rw
115.04 TRIPPED SPD FBK TRIP BOOL 0 : FALSE
1 : TRUE
FALSE ro Output
117.01 OWN ID FIREWIRE INT _ 99 ro Output
117.02 IRM ID FIREWIRE INT _ 99 ro Output
117.03 NUMBER OF NODES FIREWIRE INT _ 0 ro Output
117.04 CYCLE TIMER FIREWIRE INT _ 0 ro Output
117.05 BUS RESETS FIREWIRE INT _ 0 ro Output
117.06 MCAP ADVERTS FIREWIRE INT _ 0 ro Output
117.07 MAX HOPS FIREWIRE INT _ 0 ro Output
117.08 OFFSET (40.69ns) FIREWIRE INT _ 0 ro Output
117.13 BAD MESSAGES FIREWIRE INT _ 0 ro Output
117.14 MISSED TX ACKS FIREWIRE INT _ 0 ro Output
117.15 MY BUS RESETS FIREWIRE INT _ 0 ro Output
118.01 INPUT VIRTUAL MASTER REAL -100.00 to 100.00 % 0.00 % rw

Table of Contents

Other manuals for Parker ac890

Related product manuals