Setting up Compax3
I11 T11 192-120101 N6 - March 2004 49
4.1.5.4 Software end limits
The travel range is defined via the negative and positive end limits.
0
1 2
1: negative end limit
2: positive end limit
End limit in absolute operating mode
Positioning is limited to the end limits. The drive remains in place at the end limits if
a larger destination has been specified.
V
12
1: negative end limit
2: positive end limit
The reference is the position reference point that was defined with the machine
reference and the machine reference offset.
End limit in endless operating mode
Each single positioning is limited to the end limits; the drive continues only by the
value of the end limits, even if a greater target distance was specified.
The reference is the respective current position.
After the system is turned on, the end limits refer to the current position. The end
limits do not refer to the position reference point until after a machine reference
run.
In the case of inter-axis coupling the end limits are not monitored.
Behavior after the
system is turned on
Note:

Table of Contents

Other manuals for Parker Compax3 S150 V4

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Parker Compax3 S150 V4 and is the answer not in the manual?

Parker Compax3 S150 V4 Specifications

General IconGeneral
Output Current150 A
Control TypeDigital
SeriesCompax3
ModelS150 V4
Enclosure RatingIP20
Communication InterfacesCANopen, RS-232, RS-485
Feedback OptionsResolver
Protection FeaturesOvercurrent, Overvoltage, Undervoltage, Overtemperature, Short Circuit
Relative Humidity5 to 95% non-condensing
Operating Temperature0 to +45 °C (32 to 113 °F)

Related product manuals