Setting up Compax3
66 I11 T11 192-120101 N6 - March 2004
4.3 Device status
Key:
! I0, I1, I2: Input = 24VDC
! /I0, /I1: Input = 0V
! $I2: positive edge on I2
! O1: position reached
The device can be brought into various states via the inputs:
! I0: no Stop
! I1: Start
Motor de-energized
Energize motor
with delay
De-energize
motor with delay
Error
De-energize
motor with
delay
Deceleration
ramp upon
error
Motor energized /
Positioning data records
disabled
Deceleration
ramp upon „Stop/
de-energize"
Motor energized-
Positioning to selected positioning data record
I2
Quit
/I2
I2
/I0
Error
with reaction 2
Error
with reaction 5
O1
/I2
I1
I1 & I0
/I2
I2
/I2
/I0