Parker EME
Setting up Compax3
I11 T11 192-120101 N6 - March 2004 65
After you have configured the Compax3 according to your application with the help
of the Compax3 ServoManager, you can now carry out the first motor movements.
In the optimising window of the Compax3 ServoManager you can run the motor in
positive or negative movement direction.
In order to be able to position according to the specified positioning data records, it
is usually necessary to carry out a machine zero run after switching on (if machine
zero has been configured). This takes place automatically with the first START
after Power On. For this purpose the machine zero proximity switch must be
connected to X12/14.
When sequential positioning mode has been chosen the first positioning takes
place in response to a START signal (X12/7=24VDC).
In single positioning mode the desired positioning data record is selected via the
digital inputs I3-I7(I6) (plug X12 (see on page 28 )) and activated via a START
signal (X12/7=24VDC)
Travel via Manual+
and Manual-
Positioning

Table of Contents

Other manuals for Parker Compax3 S150 V4

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Parker Compax3 S150 V4 and is the answer not in the manual?

Parker Compax3 S150 V4 Specifications

General IconGeneral
Output Current150 A
Control TypeDigital
SeriesCompax3
ModelS150 V4
Enclosure RatingIP20
Communication InterfacesCANopen, RS-232, RS-485
Feedback OptionsResolver
Protection FeaturesOvercurrent, Overvoltage, Undervoltage, Overtemperature, Short Circuit
Relative Humidity5 to 95% non-condensing
Operating Temperature0 to +45 °C (32 to 113 °F)

Related product manuals