4
56 Workshop Manual, TPD 1377E, issue 4
100 Series
Connecting rod
To inspect Operation 4-8
Special requirements
Dimension mm (in)
Standard Service limit
Distortion for 100 (3.937) Less than 0,08 (0.0031) 0,20 (0.0079) max
Parallel for 100 (3.937) Less than 0,05 (0.0020) 0,15 (0.0059) max