6
Workshop Manual, TPD 1377E, issue 4 77
100 Series
Gear teeth backlash
To check backlash Operation 6-12
Special requirements
1
Align the set marks.
2 Measure the clearance with a feeler gauge.
Timing gear tolerances mm (in)
Standard Service limit
0,08 (0.0032) 0,25 (0.0098)