1105 [Fusing Temp.] Fusing Temperature Adjustment
(Printing Mode, Roller Type, [Color], Simplex/Duplex)
Roller Type –> Center and Ends: Heating roller, P-Roller or PR –> Pressure roller
Paper Type -> Plain, Thin, Thick, OHP, Middle Thick, Special
Printing Mode -> S: Simplex, D: Duplex
1-105-001 Fusing Ready Temp *ENG [100 to 180 / 160 / 1 deg/step]
Specifies the heating roller target temperature for the ready condition.
1-105-002 Fusing Ready: Offset *ENG [5 to 30 / 11 / 1 deg/step]
Specifies the subtracted temperature
of the heating roller for the fusing
reload start.
1-105-003 PR:RdyTrgt Temp. *ENG [50 to 160 / 120 / 1 deg/step]
Specifies the pressure roller target temperature for the ready condition.
1-105-007 P-Roll Ready Temp *ENG [0 to 150 / 20 / 1 deg/step]
Specifies the subtracted temperature of the pressure roller for the fusing reload start.
1-105-010 Stand-By: Center * ENG [50 to 180 / 160 / 1 deg/step]
Specifies the target center
temperature of the heating roller
(center) for the stand-by mode.
1-105-011 Stand-By: Ends * ENG [50 to 180 / 160 / 1 deg/step]
Specifies the target temperature of
the heating roller (ends) for the
stand-by mode.
1-105-012 Stand-By:P-Roller * ENG [50 to 160 / 140 / 1 deg/step]
Specifies the target temperature of the pressure roller for the stand-by mode.
1-105-013 Panel Off: Center * ENG [50 to 180 / 140 / 1 deg /step]
Specifies the heating roller temperature (center) in the panel off mode.
1-105-014 Panel Off: Ends * ENG [50 to 180 / 140 / 1 deg /step]
Specifies the heating roller temperature (both ends) in the panel off mode.