1-105-015 Panel Off: P-Roller *ENG [50 to 160 / 120 / 1 deg /step]
Specifies the presure roller temperature in the panel off mode.
1-105-016 Low Power: Center *ENG Specifies the heating roller
temperature (center or ends) in the
low power mode.
[30 to 180 / 40 / 1 deg /step]
1-105-017 Low Power: Ends *ENG
1-105-018 Low Power: P-Roller *ENG [30 to 160 / 110 / 1 deg /step]
Specifies the pressure roller temperature in the low power mode.
1-105-019 Off Mode: Center *ENG Specifies the heating roller
temperature (center or ends) in the
sleep mode.
[0 to 180 / 0 / 1 deg /step]
1-105-020 Off Mode: Ends *ENG
1-105-021 Off Mode:P-Roller *ENG [0 to 170 / 0 / 1 deg /step]
Specifies the pressure roller temperature in the sleep mode.
030 to 239 The target fusing temperature for each paper type and mode can be adjusted by the
following SPs.
1-105-030 Plain:FC:S:Center *ENG [100 to 180 / 155 / 1 deg /step]
1-105-031 Plain1:FC:S:Ends *ENG
1-105-032 Plain:FC:D:Center *ENG
1-105-033 Plain1:FC:D:Ends *ENG
1-105-034 Plain:BW:S:Center *ENG
1-105-035 Plain1:BW:S:Ends *ENG
1-105-036 Plain:BW:D:Center *ENG
1-105-037 Plain1:BW:D:Ends *ENG
Engine SP Mode Tables: SP1000
277