1-113-003 WaitTime AF Rcvry *ENG [0 to 60 / 10 / 1 sec/step]
Specifies the time for keeping the target temperature without any jobs after recovery
(SP1105-083).
1-113-004 Wait Time AF Job *ENG [0 to 60 / 10 / 1 sec/step]
Specifies the time for keeping the target temperature without any jobs after a last job.
1-113-005 PR Thresh AF Rdy *ENG [0 to 160 / 120 / 1 deg/step]
Specifies the threshold temperature of the pressure roller for entering the wait time
mode (SP1-113-001).
1-113-006 PR Thresh AF Job *ENG [0 to 160 / 100 / 1 deg/step]
Specifies the threshold temperature of the pressure roller for entering the wait time
mode (SP1-113-004).
1-113-008 On/Off SW Timer *ENG [0 to 999 / 300 / 1 sec/step]
Specifies the interval for entering the PID control from the On/Off control.
1115 [Stand-by Idling]
1-115-001 Interval *ENG [0 to 240 / 60 / 1 min/step]
Specifies the interval between idling during stand-by mode.
This idling during the stand-by mode prevents the roller deformation.
1-115-002 Idling Time *ENG [0 to 60 / 2 / 0.1 sec/step]
Specifies the length of each idling operation during stand-by mode.
1-115-003 Idling Speed *ENG [0 or 1 / 0 / 1 /step]
0: Half SPD, 1: Full SPD
Selects the line speed for the stand-by
idling.
1116 [Fusing Temp Change]
Paper Type –> MThick: Middle Thick
5. System Maintenance Reference
286