1-109-002 Pre-Idling Time *ENG [0 to 120 / 0 / 1 sec/step]
Specifies the fusing rotation time before executing SP1109-001.
1-109-003 Stop Time * ENG [5 to 30 / 20 / 1 sec/step]
Specifies the time for measuring the nip.
1112 [Env.Crrct:Fusing]
1-112-001 Temp.:Thresh:Low *ENG [10 to 23 / 17 / 1 deg/step]
Specifies the threshold temperature for low temperature condition.
1-112-002 Temp.:Thresh:High *ENG [24 to 40 / 30 / 1 deg/step]
Specifies the threshold temperature for high temperature condition.
1-112-003 Low Temp Correct *ENG [0 to 15 / 5 / 1 deg/step]
Specifies the temperature correction for the heating roller. When the low temperature
condition (specified with SP1112-001) is detected, the value of this SP is added to the
heating roller temperature.
1-112-004 High Temp Correct *ENG [0 to 15 / 3 / 1 deg/step]
Specifies the temperature correction for the heating roller. When the high temperature
condition (specified with SP1112-002) is detected, the value of this SP is subtracted
from the heating roller temperature.
1-112-005 J-Lo Temp. Corr *ENG [0 to 15 / 5 / 0.1 deg/step]
Specifies the temperature correction in the paper feeding for the heating roller.
1-112-006 J-Hi Temp. Corr *ENG [0 to 15 / 3 / 0.1 deg/step]
Specifies the temperature correction in the paper feeding for the heating roller.
1113 [Standby Mode Set]
1-113-001 Wait Time AF Ready *ENG [0 to 60 / 30 / 1 sec/step]
Specifies the time for keeping the target temperature without any jobs after reloading
(SP1105-082).
Engine SP Mode Tables: SP1000
285