1-116-022 C-Temp1:Mthick *ENG [-10 to 10 / 0 / 1 deg/step]
1-116-023 EndTemp1:MThick *ENG
1-116-024 C-Temp2:Mthick *ENG
1-116-025 EndTemp2:MThick *ENG
1-116-030 CenterTemp1:Other *ENG
1-116-031 EndTemp1:Other *ENG
1-116-032 CenterTemp2:Other *ENG
1-116-033 EndTemp2:Other *ENG
1118 [Curl Correction]
1-118-001 Execute Pattern *ENG [0 to 4 / 0 / 1]
Selects the curl correction mode.
0: No curl correction mode
1: Plain in 600 dpi mode
2: Plain in 1200 dpi mode
3: Curl coefficient correction
• This SP is not effective for all curl situations. Use this SP if you see a sharp back
curl after the machine recovered from "OFF mode" in a high temperature and
humidity environment.
1-118-002 Humidity Thresh 1 *ENG [0 to 100 / 65 / 1 %]
Specifies the first threshold humidity for executing the curl correction.
1-118-003 Humidity Thresh 2 *ENG [0 to 100 / 80 / 1 %]
Specifies the second threshold humidity for executing the curl correction.
-004 to
-007
Specifies the additional temperature to the target temperature of the heating roller and
pressure roller when the curl correction mode 1 or 3 is selected with SP1-118-001.
1-118-004 Pattern1:MM:HRoll *ENG [-30 to 0 / -3 / 1 deg]
1-118-005 Pattern1:MM:PRoll *ENG [0 to 60 / 0 / 1 deg]
5. System Maintenance Reference
288