Item SP No. Function Default
Meter Click
Charge
SP5-930-001 Enables or disables Meter Click Charge.
When enabled:
• The counter menu shows
immediately after you push the
"Menu" key. The "Counter Method"
(SP5-045) sets the type of the
counter.
• You can print the counter from the
counter menu.
When disabled:
• The counter menu does not show.
"0": OFF
Meter Click
Charge:
PCDU
SP5-930-010 Enables or disables the PM alert for the
PCDUs.
If this SP is enabled, an alert message is
displayed when the PCDUs need to be
replaced.
"1": No alert
Meter Click
Charge:
Image
Transfer Belt
Unit
SP5-930-014 Enables or disables the PM alert for the
image transfer belt unit.
If this SP is enabled, an alert message is
displayed when the image transfer belt
unit needs to be replaced.
"1": No alert
Meter Click
Charge:
Fusing Unit
SP5-930-016 Enables or disables the PM alert for the
fusing unit.
If this SP is enabled, an alert message is
displayed when the fusing unit needs to
be replaced.
"1": No alert
Counter
method
SP5-045-001 Specifies if the counting method used in
meter charge mode is based on
developments or prints.
"1": Prints
2. Installation