No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
203 D Polygon motor error 2: OFF timeout
The polygon mirror motor does leave the READY status within 3 seconds after the
polygon motor switches off.
• Disconnected or defective harness to polygon motor driver board
• Defective polygon motor driver board
• Defective polygon motor
1. Check or replace the harness.
2. Replace the laser unit.
3. Replace the controller.
4. Replace the BCU.
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
204 D Polygon motor error 3: XSCRDY signal error
The polygon ready (SCRDY_N) signal goes HIGH (inactive) while the laser diode
is firing.
• Disconnected or defective harness to polygon motor driver board
• Defective polygon motor
• Defective polygon motor driver board
1. Check or replace the harness.
2. Replace the laser unit.
3. Replace the controller.
4. Replace the BCU.
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
220
-001
D Laser synchronizing detection error: start position [K]: LD1
222
-004
D Laser synchronizing detection error: start position [Y]: LD1
SC Tables