STATus:QUEStionable:ACPLimit Register
The STATus:QUEStionable:ACPLimit register contains information about the results of
a limit check during ACLR measurements. A separate ACPLimit register exists for
each active channel.
You can read out the register withSTATus:QUEStionable:ACPLimit:CONDition?
or STATus:QUEStionable:ACPLimit[:EVENt]?
Table 10-8: Meaning of the bits used in the STATus:QUEStionable:ACPLimit register
Bit No. Meaning
0 ADJ UPPer FAIL
This bit is set if the limit is exceeded in the upper adjacent channel
1 ADJ LOWer FAIL
This bit is set if the limit is exceeded in the lower adjacent channel.
2 ALT1 UPPer FAIL
This bit is set if the limit is exceeded in the upper 1st alternate channel.
3 ALT1 LOWer FAIL
This bit is set if the limit is exceeded in the lower 1st alternate channel.
4 ALT2 UPPer FAIL
This bit is set if the limit is exceeded in the upper 2nd alternate channel.
5 ALT2 LOWer FAIL
This bit is set if the limit is exceeded in the lower 2nd alternate channel.
6 ALT3 … 11 LOWer/UPPer FAIL
This bit is set if the limit is exceeded in one of the lower or upper alternate channels 3 … 11.
7 CACLR FAIL
This bit is set if the limit is exceeded in one of the gap (CACLR) channels.
8 to 14 Unused
15 This bit is always 0.
STATus:QUEStionable:EXTended Register
The STATus:QUEStionable:EXTended register contains further status information
not covered by the other status registers of the R&S FSW. A separate EXTended reg-
ister exists for each active channel.
You can read out the register with STATus:QUEStionable:EXTended:
CONDition? or STATus:QUEStionable:EXTended[:EVENt]?