EasyManua.ls Logo

Rohde & Schwarz FSW26 - Measuring the Channel Power and ACLR

Rohde & Schwarz FSW26
1150 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Remote Commands
R&S
®
FSW
700User Manual 1173.9411.02 ─ 19
Manual operation: See "Selected Trace" on page 153
11.5.3 Measuring the Channel Power and ACLR
All remote control commands specific to channel power or ACLR measurements are
described here.
See also chapter 11.5.2, "Configuring Power Measurements", on page 695.
Managing Measurement Configurations............................................................... 700
Configuring the Channels......................................................................................701
Defining Weighting Filters..................................................................................... 705
Selecting the Reference Channel......................................................................... 707
Checking Limits.....................................................................................................708
General ACLR Measurement Settings..................................................................712
Configuring MSR ACLR Measurements............................................................... 713
Performing an ACLR Measurement......................................................................721
Analyzing Measurement Results...........................................................................721
Programming Examples for Channel Power Measurements................................ 722
11.5.3.1 Managing Measurement Configurations
The following commands control measurement configurations for ACLR measure-
ments.
CALCulate<n>:MARKer<m>:FUNCtion:POWer:PRESet.................................................... 700
CALCulate<n>:MARKer<m>:FUNCtion:POWer:STANdard:CATalog?................................. 701
CALCulate<n>:MARKer<m>:FUNCtion:POWer:STANdard:DELete.....................................701
CALCulate<n>:MARKer<m>:FUNCtion:POWer:STANdard:SAVE....................................... 701
CALCulate<n>:MARKer<m>:FUNCtion:POWer:PRESet <Standard>
This command loads a measurement configuration.
The measurement configuration for power measurements consists of weighting filter,
channel bandwidth and spacing, resolution and video bandwidth, detector and sweep
time.
If the "Multi-Standard Radio" standard is selected (see "Standard" on page 150), differ-
ent commands are required to configure ACLR measurements (see chapter 11.5.3.7,
"Configuring MSR ACLR Measurements", on page 713).
Parameters:
<Standard> For more information see chapter 5.3.9, "Reference: Predefined
CP/ACLR Standards", on page 183.
If you want to load a customized configuration, the parameter is
a string containing the file name.
Configuring and Performing Measurements

Table of Contents

Other manuals for Rohde & Schwarz FSW26

Related product manuals