Remote Commands
R&S
®
FSW
821User Manual 1173.9411.02 ─ 19
//Result example:
-105.225059509,-105.656074524,-105.423065186,-104.374649048,-103.059822083,-101.29511261,
-99.96534729,-99.7452468872,-99.6610794067,-100.327224731,-100.96686554,-101.450386047,
-102.150642395,-103.240142822,-105.95476532,-110.583129883,-115.7760849,-126.279388428,
-124.620399475,-116.97366333
11.6 Configuring the Result Display
The commands required to configure the screen display in a remote environment are
described here.
The tasks for manual operation are described in chapter 7.1, "Result Display Configu-
ration", on page 440.
● General Window Commands................................................................................ 821
● Working with Windows in the Display................................................................... 822
● Examples: Configuring the Result Display............................................................827
11.6.1 General Window Commands
The following commands are required to configure general window layout, independent
of the application.
Note that the suffix <n> always refers to the window in the currently selected measure-
ment channel (see INSTrument[:SELect] on page 686).
DISPlay:FORMat........................................................................................................... 821
DISPlay[:WINDow<n>]:SIZE........................................................................................... 821
DISPlay:FORMat <Format>
This command determines which tab is displayed.
Parameters:
<Format> SPLit
Displays the MultiView tab with an overview of all active chan-
nels
(See chapter 4.1, "R&S MultiView", on page 97).
SINGle
Displays the measurement channel that was previously focused.
*RST: SING
Example:
DISP:FORM SPL
DISPlay[:WINDow<n>]:SIZE <Size>
This command maximizes the size of the selected result display window temporarily.
To change the size of several windows on the screen permanently, use the LAY:SPL
command (see LAYout:SPLitter on page 825).
Configuring the Result Display