Network and Remote Operation
R&S
®
FSW
658User Manual 1173.9411.02 ─ 19
for use in production. The computer that is used for remote operation is called "control-
ler" here. The following tasks can be performed using Remote Desktop:
Access to the control functions via a virtual front panel (soft front panel)
Printout of measurement results directly from the controller
Storage of measured data on the controller's hard disk
This documentation provides basic instructions on setting up the Remote Desktop for
the R&S FSW. For details refer to the Windows 7 operating system documentation.
10.5.1 How to Configure a Network
A precondition for operating or monitoring the R&S FSW remotely is that it is connec-
ted to a LAN network or a PC connected to the GPIB interface. This is described here.
Windows Firewall Settings
A firewall protects an instrument by preventing unauthorized users from gaining access
to it through a network. Rohde & Schwarz highly recommends the use of the firewall on
your instrument. R&S instruments are shipped with the Windows firewall enabled and
preconfigured in such a way that all ports and connections for remote control are
enabled. For more details on firewall configuration see the R&S White Paper "Malware
Protection" (available at http://www.rohde-schwarz.com/appnote/1EF73) and the Win-
dows 7 help system.
10.5.1.1 How to Connect the Instrument to the Network
There are two methods to establish a LAN connection to the instrument:
A non-dedicated network (Ethernet) connection from the instrument to an existing
network made with an ordinary RJ-45 network cable. The instrument is assigned
an IP address and can coexist with a computer and with other hosts on the same
network.
A dedicated network connection (Point-to-point connection) between the instru-
ment and a single computer made with a (crossover) RJ-45 network cable. The
computer must be equipped with a network adapter and is directly connected to the
instrument. The use of hubs, switches, or gateways is not required, however, data
transfer is still performed using the TCP/IP protocol. An IP address has to be
assigned to the instrument and the computer, see chapter 10.5.1.2, "How to Assign
the IP Address", on page 659.
Note: As the R&S FSW uses a 1 GBit LAN, a crossover cable is not necessary
(due to Auto-MDI(X) functionality).
To establish a non-dedicated network connection, connect a commercial RJ-45
cable to one of the LAN ports.
To establish a dedicated connection, connect a (crossover) RJ-45 cable between
the instrument and a single PC.