Remote Commands
R&S
®
FSW
706User Manual 1173.9411.02 ─ 19
[SENSe:]POWer:ACHannel:FILTer:ALPHa:CHANnel<ch> <Alpha>
This command defines the roll-off factor for the transmission channel weighting filter.
Parameters:
<Alpha> Roll-off factor
Range: 0 to 1
*RST: 0.22
Manual operation: See "Weighting Filters" on page 158
[SENSe:
]POWer:ACHannel:FILTer[:STATe]:ACHannel <State>
This command turns the weighting filter for the adjacent channel on and off.
Parameters:
<State> ON | OFF
*RST: OFF
Manual operation: See "Weighting Filters" on page 158
See "Weighting Filters" on page 170
[SENSe:]POWer:ACHannel:FILTer[:STATe]:ALL <State>
This command turns the weighting filters for all channels on and off.
Parameters:
<State> ON | OFF
*RST: OFF
[SENSe:]POWer:ACHannel:FILTer[:STATe]:ALTernate<ch> <State>
This command turns the weighting filter for an alternate channel on and off.
Parameters:
<State> ON | OFF
*RST: OFF
Manual operation: See "Weighting Filters" on page 158
See "Weighting Filters" on page 170
[SENSe:]POWer:ACHannel:FILTer[:STATe]:CHANnel<ch> <State>
This command turns the weighting filter for a transmission channel on and off.
Parameters:
<State> ON | OFF
*RST: OFF
Manual operation: See "Weighting Filters" on page 158
Configuring and Performing Measurements