EasyManua.ls Logo

Rohde & Schwarz FSW26 - Page 872

Rohde & Schwarz FSW26
1150 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Remote Commands
R&S
®
FSW
872User Manual 1173.9411.02 ─ 19
Band Frequency start [GHz] Frequency stop [GHz]
D 110.0 170.0
G 140.0 220.0
J 220.0 325.0
Y 325.0 500.0
USER 32.18
(default)
68.22
(default)
*) The band formerly referred to as "A" is now named "KA".
[SENSe:]MIXer:HARMonic:HIGH:STATe <State>
This command specifies whether a second (high) harmonic is to be used to cover the
band's frequency range.
Parameters:
<State> ON | OFF
*RST: OFF
Example:
MIX:HARM:HIGH:STAT ON
Manual operation: See "Range 1/2" on page 369
[SENSe:]MIXer:HARMonic:HIGH[:VALue] <HarmOrder>
This command specifies the harmonic order to be used for the high (second) range.
Parameters:
<HarmOrder numeric value
Range: 2 to 61 (USER band); for other bands: see band
definition
Example:
MIX:HARM:HIGH 2
Manual operation: See "Harmonic Order" on page 369
[SENSe:]MIXer:HARMonic:TYPE <OddEven>
This command specifies whether the harmonic order to be used should be odd, even,
or both.
Which harmonics are supported depends on the mixer type.
Parameters:
<OddEven> ODD | EVEN | EODD
*RST: EVEN
Example:
MIX:HARM:TYPE ODD
Manual operation: See "Harmonic Type" on page 369
Setting Basic Measurement Parameters

Table of Contents

Other manuals for Rohde & Schwarz FSW26

Related product manuals